Local care · Family business since 1984Engineer visits Monday–Thursday

BROWSE BY FITTING OR SYMPTOM

Plumbing guidance

Find a useful starting point for taps, toilets, showers, visible leaks, supply changes, ordinary drainage and heating controls.

What has changed?

104 individual plumbing guides in this edition.

Search plumbing guidance

Taps & outlets

Drips, flow and controls.

Plumbing

A CoolStart basin tap runs cold with the handle in the centre

Some mixer taps deliberately start with cold water in the central position. Check the control design before reporting a missing hot supply.

Read the guide
Plumbing

A bath mixer stays on the shower outlet after the water is turned off

Some bath diverters automatically return to the spout, while others retain their setting. Establish the designed action before reporting a sticking control.

Read the guide
Plumbing

A pull-out kitchen tap hose will not return into the spout

A clear route inside the cupboard matters to a pull-out hose. Check for stored objects before assuming the spray head needs replacement.

Read the guide
Plumbing

A tap serving an open-vented water heater drips while it heats

The outlet on a suitable open-vented heater arrangement has a specific role. Confirm the system before treating every heating-time drip as valve failure.

Read the guide
Plumbing

Both spray patterns run together on a pull-out kitchen tap

When stream and spray no longer separate, record the selector behaviour and identify the pull-out head before replacing the complete tap.

Read the guide
Plumbing

Can the kitchen tap move out of the way of an opening window?

Only a tap designed for window clearance should be lifted or tilted. Identify the mechanism and available space before moving a fixed fitting.

Read the guide
Plumbing

Does a hansgrohe Select kitchen tap button need a battery?

A mechanical Select button can pause the flow or select an outlet, depending on the tap. Identify its purpose before treating it as a failed sensor.

Read the guide
Plumbing

Does a tap drip briefly after use or continue all day?

A short release of water remaining in the spout needs a different description from a drip that never stops after the handle is closed.

Read the guide
Plumbing

One basin tap has lost flow while other outlets remain normal

An outlet aerator can restrict a single tap. Identify the removable part and permitted cleaning method before assuming the household supply needs upgrading.

Read the guide
Plumbing

The basin tap jet splashes because it lands in the wrong place

A water-stream direction problem needs the basin and tap combination considered. An adjustable aerator is only useful when it fits the exact outlet.

Read the guide
Plumbing

The bath fills normally but its shower handset has weak flow when raised

On a gravity-fed bath shower mixer, handset height can affect the available supply conditions. A satisfactory bath-spout flow does not confirm shower performance.

Read the guide
Plumbing

The new tap has much weaker flow than the old one

A change after tap replacement calls for a compatibility and installation check before the household water pressure is blamed.

Read the guide
Plumbing

The sensor tap keeps starting while the basin is cleaned

Some electronic taps provide a cleaning mode. Find the model-specific control method before treating normal sensor activation as a fault.

Read the guide
Plumbing

The tap controls seem reversed after repair or installation

A changed opening direction and hot water appearing at a cold-marked control are different problems. Describe which has changed before another part is ordered.

Read the guide
Plumbing

The tap finish looks marked after a cleaning product was used

A surface-care problem needs the finish and cleaner identified. Stronger chemicals or abrasive polishing can make assessment harder.

Read the guide
Plumbing

Water leaks from the swivel joint when the kitchen tap runs

A wet rotating joint is different from water dripping out of the spout. Identify the joint and the movement that accompanies the leak.

Read the guide

Toilets & cisterns

Filling, flushing and running water.

Plumbing

A toilet flush has gradually weakened although the cistern refills

A weak rinse around the bowl differs from a cistern that will not fill or a drain that is backing up. Describe the actual water movement before changing settings.

Read the guide
Plumbing

Can a cistern cleaning block interfere with a drop flush valve?

A product placed inside the cistern can affect its mechanism. Keep the product details and describe any change in flushing or sealing.

Read the guide
Plumbing

Does a concealed cistern need access from the top or the front?

The visible flush control does not establish the service opening. Identify the cistern before lifting a worktop or removing a furniture panel.

Read the guide
Plumbing

Does a failed Dudley Turbo toilet syphon mean replacing the whole cistern?

A serviceable two-part syphon can change the repair options. Identify the fitted assembly before assuming that the complete toilet must be removed.

Read the guide
Plumbing

The cistern pauses before refilling after a new valve was fitted

A water-saving delayed-fill valve can intentionally wait until flushing has finished. Check the valve type and the complete sequence.

Read the guide
Plumbing

The concealed toilet flush became stiff after a furniture panel changed

Button position and cable routing can matter on a cable-operated cistern. A problem beginning after panel work should be described as a change in the installation.

Read the guide
Plumbing

The toilet cistern takes much longer to refill

Slow filling concerns the incoming-water stage. Describe it separately from a weak flush or a toilet bowl that drains poorly.

Read the guide
Plumbing

Water appears outside the toilet around the cistern-to-pan joint

An external leak needs its first wet point and timing recorded. Water trickling inside the bowl follows a different route from water escaping around a cistern joint.

Read the guide
Plumbing

Water keeps trickling into the toilet bowl after refilling

Continuing water in the pan can come from different cistern functions. Report the refill behaviour and any external leak without guessing which valve to buy.

Read the guide
Plumbing

Why a replacement toilet fill valve must match the cistern entry

The inlet location and available space affect a fill-valve replacement. A universal description does not eliminate the need to check the existing connection.

Read the guide
Plumbing

Why does holding a Fluidmaster syphon lever give a smaller flush?

Some dual-flush syphons use the lever differently from a two-button valve. Confirm the fitted mechanism before assuming the full flush has failed.

Read the guide
Plumbing

Why the stated size of a toilet syphon is not its overall height

Replacement syphons are selected around the cistern’s working dimensions. Measuring only the top of the old assembly can produce a misleading match.

Read the guide
Plumbing

Will a new Geberit flush plate fit the existing concealed cistern?

The cistern family determines flush-plate compatibility. Matching a plate’s colour or outer dimensions is not enough to confirm the operating mechanism.

Read the guide

Showers

Temperature, flow and shower type.

Plumbing

A Mira electric shower stops as soon as the button is released

Immediate stopping is useful diagnostic information. Note the lights and installation history, then leave casing and electrical checks to an appropriate professional.

Read the guide
Plumbing

A Satellites LP digital shower starts and stops after a few seconds

Loss of either water supply can make this thermostatic digital shower stop. Record the recent supply history before treating the symptom as a timer setting.

Read the guide
Plumbing

A Triton Amore keeps flowing briefly while the display says Bye

The Amore’s documented shutdown includes a short water flush. Distinguish a completed shutdown sequence from water that continues without stopping.

Read the guide
Plumbing

A Triton Satellites LP shower is being kept after a supply-system upgrade

An existing low-pressure digital shower may not suit a new mains-pressure system. Check the mixing unit before the household plumbing is changed.

Read the guide
Plumbing

An electric shower displays a low-pressure warning

A low-pressure indication needs a supply and restriction assessment. The warning alone does not establish that the shower’s heater has failed.

Read the guide
Plumbing

Can an electric shower be replaced with a higher-kilowatt model?

The available electrical supply, water connections and fitting dimensions must all be checked. A similar case shape does not establish a suitable replacement.

Read the guide
Plumbing

Can one Triton Satellites mixing unit serve two shower rooms?

Independent controllers and a shared mixing unit are different arrangements. Confirm the system design before connecting another room to an existing digital shower.

Read the guide
Plumbing

How to check the Triton T80 Pro-Fit product safety notice

Match the exact shower name and manufacturing date to Triton’s notice. The manufacturer should confirm whether a particular unit needs its safety inspection.

Read the guide
Plumbing

Is the shower electric, a mixer, a power shower or digital?

The shower type changes which supply and controls matter. Identify the actual product before describing a heating or flow fault.

Read the guide
Plumbing

The digital shower controller shows Out of Range

A local controller warning needs the shower’s own power and radio arrangement considered. It does not by itself prove that the home internet has failed.

Read the guide
Plumbing

The digital shower stops earlier than expected

A repeatable stopping point can involve an enabled user mode. Record the controller state and timing before assuming the mixing unit has failed.

Read the guide
Plumbing

The electric shower feels different in winter and summer

Incoming water temperature can change the balance between warmth and flow. Separate a seasonal adjustment from a sudden or unsafe fault.

Read the guide
Plumbing

The mixer shower stays lukewarm on a high-pressure supply

A high-pressure mixer needs its hot supply and fitted outlet arrangement considered together. A cold shower does not identify a cartridge fault by itself.

Read the guide
Plumbing

The mixer shower temperature changes when another outlet is used

A toilet refill or appliance water intake can matter as well as another tap. Record the household sequence without deliberately recreating a hot-water surge.

Read the guide
Plumbing

The overhead shower releases water after it has been switched off

A brief release of retained water is different from an outlet that never stops dripping. Record the delay, duration and any connection with other outlets.

Read the guide
Plumbing

The shower changed after a replacement hose was fitted

A hose is part of the outlet arrangement. Keep the model and original accessory details when a replacement causes leakage, weak flow or a different temperature.

Read the guide
Plumbing

Water appears to leak from the electric shower casing

Keep a leaking electrical shower unused. Describe whether water is at the hose connection or emerging from the unit without opening its cover.

Read the guide

Water supply

Pressure and supply changes.

Plumbing

A Surestop remote water switch no longer turns the supply off

The remote switch uses a water-operated connection rather than electrical power. Its small tubing route is a useful observation when operation changes.

Read the guide
Plumbing

Can a delayed-fill Airgap valve be used in a loft header tank?

Similar-looking fill valves can serve different applications. The delayed-fill and non-delay versions should not be treated as interchangeable.

Read the guide
Plumbing

Cold water looks brown or orange after a supply interruption

A change following mains work needs the timing and affected properties recorded. Use the water supplier’s current advice before treating it as a tap fault.

Read the guide
Plumbing

Milky tap water clears from the bottom of a standing glass

The way cloudiness clears is useful information for the water supplier. Keep it separate from coloured water or persistent solid particles.

Read the guide
Plumbing

Prepare an outside tap and hose before freezing weather

Disconnecting the hose and checking outside-tap isolation are separate from dealing with a pipe that is already frozen. Plan access while the fittings still operate normally.

Read the guide
Plumbing

The pipes bang when a tap or appliance stops taking water

Record the event that triggers the sound. Pipe support, valve behaviour and supply conditions can all matter before a particular fitting is selected.

Read the guide
Plumbing

There is no water upstairs but the cold kitchen tap still works

Which outlets still work helps distinguish a household plumbing issue from a wider supply interruption. Record the pattern before choosing whom to contact.

Read the guide
Plumbing

Water returns after a frozen pipe, but the area is now wet

A thaw can reveal pipe damage that was hidden while the water was frozen. Returning flow is not proof that the pipe is sound.

Read the guide
Plumbing

Which stop valve should be used to isolate water inside the home?

The internal stop valve is normally the first control for household isolation. An external valve can serve a different section of pipe or a shared supply.

Read the guide

Visible leaks

Location, timing and access.

Ordinary drainage

Slow outlets and backing-up water.

Plumbing

A shower waste behaves differently after its removable insert was cleaned

Some shower traps have a removable dip tube and seal. Refitting the correct pieces matters as much as removing hair and debris.

Read the guide
Plumbing

Does the new basin waste match the basin’s overflow arrangement?

A combined waste may need a different configuration for a basin with no overflow. Confirm the basin and waste details before treating every supplied spacer as optional.

Read the guide
Plumbing

One drain is slow, or several fixtures are backing up together

The number and location of affected fixtures help route an ordinary drainage enquiry. Avoid adding water to a system that is already backing up.

Read the guide
Plumbing

The basin has a mushroom waste cover but it will not close

An always-open waste can resemble a push-button plug. Identify the fitted design before forcing it or ordering a replacement spring mechanism.

Read the guide
Plumbing

The basin trap gurgles when another fixture empties

A sound triggered by a different waste outlet can involve the shared drainage arrangement. Identify the sequence before replacing the basin trap.

Read the guide
Plumbing

The waste fitting is straight instead of a U-bend: could it be HepvO?

A self-sealing waste valve works differently from a conventional water-filled trap. Identify the fitting before assuming a missing bend or water seal is the fault.

Read the guide
Plumbing

Water builds up in the shower tray after a shower upgrade

The tray, waste fitting and connected pipework need to suit the incoming flow. A larger shower outlet does not automatically come with a higher-capacity drain.

Read the guide

Heating & controls

Radiators, user controls and visible system behaviour.

Plumbing

Can a heating pump have a dark display while its summer mode is active?

The covered Grundfos ALPHA2 range has a manual summer mode from model C onward. Its instructions describe the display being off while the pump remains available for brief low-speed operation intended to reduce the risk of the rotor becoming stuck.

Read the guide
Plumbing

Can a radiator valve in the thermostat room stop the heating controls agreeing?

A traditional room thermostat and a conventional TRV can influence the same room in different ways. The thermostat requests heat for the system, while the TRV restricts flow through its radiator according to the air temperature near the valve.

Read the guide
Plumbing

Can existing smart radiator heads join any new heating hub?

Matching a manufacturer's name does not establish that two smart-heating products belong to the same system. Danfoss explicitly distinguishes standalone Eco thermostats from the Connect thermostats used with its Link controller; adding a hub does not convert one into the other.

Read the guide
Plumbing

Could a curtain or sofa make a radiator valve shut down too soon?

A thermostatic radiator valve senses air near its head. If a curtain, cover or piece of furniture encloses that small area, the valve may experience different conditions from the part of the room where people are sitting.

Read the guide
Plumbing

Does a passing inhibitor test prove the whole heating system is healthy?

A test result answers the question that the test is designed to measure. Fernox's Express Inhibitor Test checks the concentration of molybdate-based inhibitor; it is not a direct measurement of radiator flow, pump operation or every aspect of water condition.

Read the guide
Plumbing

Does a radiator that is cold at the bottom need the same treatment as trapped air?

The location of a cold area matters. Stelrad associates a persistently cold lower section with restricted circulation from accumulated debris; releasing trapped air addresses a different problem. Repeatedly opening a bleed point is not a general cure for every uneven radiator.

Read the guide
Plumbing

Does a red light on a smart radiator head always mean the batteries are low?

Colour alone is not enough to identify every radiator-thermostat warning. Wiser's LED guide distinguishes battery states, missing signal and other operating states using the light's position, pattern and the action that triggered it.

Read the guide
Plumbing

Does draining a radiator for work affect the heating system's inhibitor protection?

Heating-system protection should be reviewed after water has been drained and replaced. Fernox's treatment guidance specifically includes radiator removal for decorating as an occasion to check and restore inhibitor protection, rather than assuming the earlier treatment remains unchanged.

Read the guide
Plumbing

Does having a magnetic filter mean the heating system cannot contain sludge?

A magnetic heating filter is intended to capture material carried in the circulating water. Its presence does not establish that every radiator is already clean or that the filter has been maintained. Existing deposits and ongoing protection are separate questions.

Read the guide
Plumbing

Does selecting Heating Off mean frost protection is also disabled?

Off can be a control mode rather than complete electrical isolation. The evohome user guide identifies its off state with frost protection, so an occasional protective demand can have a different meaning from the normal comfort schedule starting unexpectedly.

Read the guide
Plumbing

How should a radiator be cleaned without damaging its finish?

Surface dust and a damaged coating need different treatment. Stelrad's cleaning guidance recommends a non-abrasive, pH-neutral soap and careful drying for the relevant finish; aggressive pads or chemicals can turn an ordinary cleaning task into permanent surface damage.

Read the guide
Plumbing

Is a radiator's clicking noise different from bubbling or persistent banging?

The timing and character of a radiator noise matter. Stelrad describes light clicking during warming or cooling as a possible result of metal expanding or contracting. A new continuous water sound or forceful banging needs a different description and assessment.

Read the guide
Plumbing

Should heating pressure be compared when the system is hot or cold?

Compare pressure readings under the same operating conditions. Worcester Bosch's guidance distinguishes the cool-system pressure from its rise during heating and directs owners to an installer when topping up becomes unusually frequent or the rise is excessive.

Read the guide
Plumbing

Should the heating controller use the same batteries as its radiator heads?

Different devices in one heating system can require different batteries. The evohome touchscreen controller uses rechargeable cells and a powered stand or wall bracket for charging; its requirements should not be inferred from a battery-operated radiator head.

Read the guide
Plumbing

What does the number on a heating circulation pump actually measure?

On the covered Grundfos ALPHA2 models, the display can show electrical consumption in watts or an indicated flow rate in cubic metres per hour. Neither number is the room temperature or the heat output of the whole heating system.

Read the guide
Plumbing

What should I record if water appears below a radiator?

Water below a radiator may originate at a valve, connection, bleed point or the panel itself. The first wet location and surrounding corrosion are useful evidence, but the lowest drip point does not necessarily identify the source above it.

Read the guide
Plumbing

What should be recorded when an ALPHA2 heating pump shows an E warning?

A warning on the pump needs its own model context. The cited Grundfos ALPHA2 table distinguishes E1 rotor blockage, E2 insufficient supply voltage and E3 an electrical fault; covered versions with dry-running protection also use E4 for that protective state.

Read the guide
Plumbing

Why are all the heating events an hour early or late?

When every event moves by the same amount, check the controller's clock, date and daylight-saving state before editing each programmed period. A uniform time shift is different from a learning mode choosing a variable early start on colder days.

Read the guide
Plumbing

Why can I control a heating thermostat from nearby but not from outside the home?

An app-controlled thermostat is not necessarily an internet-controlled thermostat. Danfoss Eco uses a local Bluetooth connection, and the referenced Drayton Digistat also connects to its app by Bluetooth. Their app presence alone does not establish remote access from elsewhere.

Read the guide
Plumbing

Why did a temperature change made on the radiator head not last?

A local radiator control may apply a temporary boost rather than rewrite the room's schedule. Wiser's radiator-thermostat guidance describes twisting the cap as a time-limited increase or decrease, which is different from saving a new scheduled target.

Read the guide
Plumbing

Why did editing one heating day change several days?

A controller can organise schedules as one daily pattern, a weekday/weekend pair, or separate days. The referenced Digistat offers these arrangements, so an edit made within a grouped schedule may apply more widely than the owner expected.

Read the guide
Plumbing

Why do the thermostat buttons lock while its phone app is open?

The referenced new Drayton Digistat guide describes a deliberate local-button lock while the Wiser Home app is controlling it. A lock symbol appearing during that connection can therefore reflect control ownership rather than failed buttons or a forgotten security code.

Read the guide
Plumbing

Why does a radiator without a smart head warm when another room asks for heat?

Room-by-room smart control does not automatically close every radiator in the property. An open radiator without a smart head may receive hot water whenever another room requests heating, while a conventional TRV still responds to its own local setting.

Read the guide
Plumbing

Why does a radiator's advertised wattage not guarantee the same heat in this room?

A radiator's declared heat output belongs to stated temperature conditions. Stelrad explains that the difference between radiator-water temperature and room temperature affects output, so a headline wattage cannot be assessed without its associated Delta T basis.

Read the guide
Plumbing

Why does a smart-controlled radiator keep receiving heat after it is set to Off?

A radiator cooling after use is different from one that begins heating again despite its own confirmed off command. Wiser's support guidance identifies valve compatibility, calibration and battery condition as relevant checks when its radiator thermostat cannot close the valve properly.

Read the guide
Plumbing

Why does boosting hot water not also warm the radiators?

A suitable dual-channel programmer can control stored hot-water heating separately from space heating. The Drayton Lifestyle guide distinguishes those channels, so requesting extra hot water is not automatically a request to raise the room temperature.

Read the guide
Plumbing

Why does one smart radiator pause when a window is opened?

Open-window detection can suspend heating in an affected room after a sudden temperature drop. Wiser's app guidance describes this as an optional room feature, so a pause during ventilation does not by itself mean the radiator has lost its connection.

Read the guide
Plumbing

Why does smart heating start early or stop before the scheduled period ends?

Some heating schedules describe when a room should reach its target, with the controller choosing an earlier start. Other features reduce heating before a cooler period because the home is expected to retain warmth. Both can be deliberate behaviour.

Read the guide
Plumbing

Why does the programmer keep heating available through the middle of the day?

On the referenced Drayton Lifestyle controls, ONCE uses one continuous availability period from the first programmed start to the final programmed finish. TIMED follows the separate daily periods. Choosing ONCE can therefore remove the expected gaps without changing the saved times.

Read the guide
Plumbing

Why does the smart radiator's room reading differ from a separate thermometer?

A sensor beside a radiator does not experience exactly the same conditions as a thermometer elsewhere. Wiser says its radiator thermostat applies an algorithm to estimate room temperature, whereas its separate room thermostat measures temperature at its own location.

Read the guide
Plumbing

Why does wet underfloor heating respond more slowly than the radiators?

Floor construction changes the response of wet underfloor heating. Nu-Heat explains that a thick screed stores substantial heat, while a low-profile system with pipes nearer the surface can respond more quickly. They should not be judged against one universal warm-up time.

Read the guide
Plumbing

Why has a heating target changed even though nobody edited the schedule?

Some controllers deliberately adjust heating in response to outdoor conditions. Evohome's Smart Weather features include Cold Weather Boost, which can adjust a setpoint, and Warm Weather Saver, which can limit low heating demand as outside conditions become milder.

Read the guide
Plumbing

Why has the heating controller's fault-log option disappeared?

A missing history menu does not always indicate a display fault. The evohome guide states that its fault logbook appears only when it contains an entry; after the list is cleared, the option remains absent until another issue is detected.

Read the guide
Plumbing

Why is a heating period skipped or its new time rejected?

A timed period needs a usable start and finish in the correct sequence. The Drayton Lifestyle guide deliberately uses matching middle-period start and finish times to leave that period inactive, and warns when entered events fall out of order.

Read the guide
Plumbing

Will the heating stop if the internet or phone app loses connection?

An unavailable remote app does not always mean the heating has stopped. Wiser explains that its installed controls communicate locally and can continue the previously selected programme without an internet connection, provided the heating system and controls still have power.

Read the guide
Plumbing

Will turning the radiator valve to its highest number warm the room faster?

A conventional thermostatic radiator valve responds to the air around it. Turning its setting higher asks it to maintain a warmer room; it does not make the radiator or heating source deliver an instant burst of extra power.

Read the guide

LET’S GET THE DETAILS RIGHT

Tell us what has changed.

Have the model, symptom and postcode ready. We’ll confirm suitable work and availability.

CallBook onlineRepair help