Identify a vented installation correctly
An exhaust hose carrying air outside is different from the small water-drain hose used by some condenser and heat-pump dryers. Check the model description if unsure. With the machine stopped, observe only accessible sections of the exhaust route. Record a visibly crushed hose, disconnected section, covered outlet or recent building work near the termination, without pulling the dryer out or climbing.
Keep the repair matched to the installation
Report dampness, poor drying or unusual warmth that accompanied the visible problem. The hose specification, route and outside termination should follow the manufacturer's installation instructions. Do not operate with the hose removed into the room, improvise a narrower connection or push tools along hidden ductwork. Inaccessible routing or a damaged external outlet may need an installer as well as appliance assessment.
Useful observations
- Photograph the accessible hose section and outside outlet from a safe position.
- Note whether the machine or nearby furniture was recently repositioned.
Details to include in your enquiry
- Is this definitely an air exhaust rather than a water-drain connection?
- Did the issue begin after decorating, building work or moving the appliance?
An inspection confirms the fault. Do not dismantle the appliance or reproduce an unsafe symptom to answer a question.
Further information
Your model’s instructions take precedence over general guidance.