Retain the complete display
Photograph the code so that a small 5 is not lost in a telephone description. Note whether the drum continued moving, whether the cycle stopped and how long it had been running. Do not infer actual compressor temperature from the warmth of the cabinet or laundry.
Keep refrigeration parts out of owner checks
The compressor and sealed circuit are internal service areas. Do not remove panels, press on pipes or try to add refrigerant. Record filter maintenance and room conditions that were already known during ordinary use. Follow only the safe owner response in the model manual; a recurring warning needs assessment rather than repeated starts after short pauses. Include any separate electrical trip or burning smell immediately in the report.
Useful observations
- Preserve the final 5 in the code.
- Note programme progress and known room conditions.
Details to include in your enquiry
- Is the appliance identified as a heat-pump dryer?
- Did this code recur after the documented owner response?
An inspection confirms the fault. Do not dismantle the appliance or reproduce an unsafe symptom to answer a question.
Further information
Your model’s instructions take precedence over general guidance.